Our analyses showed that the median data entry time for all hospitals combined was three minutes faster for electronic than for paper orders for each year; a significant difference. This significant difference was consistent for both tests (EUC and Automated Differential) across 2010 and 2011 (see Tables 15a and 15b). This faster data entry time translated into significantly lower median Total Laboratory TATs for electronic orders than for paper orders (for EUC tests the difference in medians was 12 minutes in 2010 and six minutes in 2011; for Automated Differential tests, the difference in medians was four minutes in 2010 and two minutes in 2011). In January 2011, the chemistry analyser in the clinical chemistry department servicing Hospitals A, B, and C, was replaced with an instrument with a longer analytical cycle time. This was the reason for an increased Total Laboratory TAT in 2011.

Clinical chemistry 2008200920102011
Hosp EUC EMR Paper EMR Paper EMR Paper EMR Paper
AMedian TAT (mins) Data Entry . 14 . 9 5 8 5 8
z=25.56, p<.001 z=17.77, p<.001
Total Lab . 42 . 47 43 56 58 64
z=20.53, p<.001 z=15.72, p<.001
Test Count . 20325 . 19757 16926 3058 17252 3616
BMedian TAT (mins)Data Entry. 12 . 9 6 8 5 6
z=7.36, p<.001 z=2.88, p<.01
Total Lab. 42 . 49 44 51 61 65
z=5.39, p<.001 z=3.38, p<.01
Test Count . 2152 . 2205 1486 504 1435 481
CMedian TAT (mins)Data Entry. 10 . 9 5 8 5 8
z=12.13, p<.001 z=12.76, p<.001
Total Lab. 40 . 51 43 59 64 70
z=12.51, p<.001 z=6.02, p<.001
Test Count . 4953 . 5142 4475 663 3886 714
DMedian TAT (mins)Data Entry. 110 12 6 8 4 9
z=4.06, p<.001 z=4.03, p<.001 z=12.64, p<.001
Total Lab. 5266 74 68 74 59 70
z=5.10, p<.001 z=3.38, p<.01 z=10.13, p<.001
Test Count . 5160 4560 357 4880 321 5134 646
EMedian TAT (mins)Data Entry. 1010 15 10 15 7 13
z=20.22, p<.001 z=25.70, p<.001 z=27.04, p<.001
Total Lab. 5052 58 79 89 67 81
z=16.38, p<.001 z=14.33, p<.001 z=22.60, p<.001
Test Count . 24266 19459 4482 20798 5071 23179 3747
FMedian TAT (mins)Data Entry. 1214 12 9 9 6 7
z=0.48, n.s. z=0.56, n.s. z=7.47, p<.001
Total Lab. 6565 72 87 88 61 65
z=16.69, p<.001 z=3.95, p<.001 z=12.43, p<.001
Test Count . 19517 15776 3950 15503 4017 16418 3345
OverallMedian TAT (mins)Data Entry7 10 6 9
z=35.16, p<.001 z=33.56, p<.001
Total Lab66 78 62 68
z=29.67, p<.001 z=30.45, p<.001
Test Count 64068 13634 67304 12549
Mann-Whitney U tests of significance; n.s.: Not Significant

Table 15a. A comparison, between electronic-orders (EMR) and paper-orders, for EUC in the clinical chemistry department, of the median test TATs for the pre-analytic data entry phase and the laboratory test process from the time a specimen was received in CSR until a result was available.

Haematology2008200920102011
HospAutomated DIffEMRPaperEMRPaperEMRPaperEMRPaper
AMedian
TAT
(mins)
Data Entry1495958
z=28.69, p<.001z=20.29, p<.001
Total Lab153328322930
z=11.34, p<.001z=5.77, p<.001
Test Count1956119121158363160162373771
BMedian
TAT
(mins)
Data Entry1696768
z=7.28, p<.001z=7.45, p<.001
Total Lab513532323031
z=0.04, n.s.z=2.57, p<.05
Test Count308729961642133316471376
CMedian
TAT
(mins)
Data Entry1295949
z=17.46, p<.001z=15.81, p<.001
Total Lab463633333232
z=0.70, n.s.z=0.81, n.s.
Test Count3963380933786363056751
DMedian
TAT
(mins)
Data Entry110126749
z=3.80, p<.001z=4.42, p<.001z=12.35, p<.001
Total Lab29424743502633
z=3.60, p<.001z=3.01, p<.01z=6.30, p<.001
Test Count4979441934647443295231688
EMedian
TAT
(mins)
Data Entry1010151015713
z=21.06, p<.001z=25.55, p<.001z=26.59, p<.001
Total Lab45434738443744
z=10.19, p<.001z=18.54, p<.001z=18.27, p<.001
Test Count22367173054791194905453214734373
FMedian
TAT
(mins)
Data Entry1213129866
z=2.41, p<.05z=0.21, n.s.z=5.56, p<.001
Total Lab74717378785864
z=1.57, n.s.z=0.06, n.s.z=2.57, p<.05
Test Count20139158384662158114417167173733
OverallMedian
TAT
(mins)
Data Entry71069
z=34.41, p<.001z=35.35, p<.001
Total Lab40443638
z=12.79, p<.001z=11.70, p<.001
Test Count60901153286436114692

Mann-Whitney U tests of significance; n.s.: Not Significant
Table 15b. A comparison, between electronic-orders (EMR) and paper-orders, for Automated Differential in haematology, of the median test TATs for the pre-analytic data entry phase, and the laboratory test process from the time a specimen was received in CSR until a result was available.